FEATURES
1. Low Impedance over wide temperature range of -40...105°C, with 5mm height.
2. Suitable for DC-DC converters where smaller case size and lower impedance are required.
 |
CASE SIZE TABLE
| ØD |
4 |
5 |
6,3 |
| F |
1,5 |
2,0 |
2,5 |
| Ød |
0,45 |
SPECIFICATIONS
| Item |
Performance Characteristics |
| Operating Temperature Range |
-55 to +105°C |
| Rated Working Voltage Range |
6,3 to 100V |
| Nominal Capacitance Range |
0,1 to 22000μF |
| Capacitance Tolerance |
±20% (120Hz, +20°C) |
| Leakage Current |
I ≤ 0,01 CV or 3μA after 2 minutes whichever is greater measured with rated working voltage applied at +20°C |
| tan δ (120Hz, +20°C) |
| Working Voltage (V) |
6,3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| tan δ (max) |
0,28 |
0,24 |
0,20 |
0,16 |
0,14 |
0,12 |
0,10 |
0,08 |
For capacitance value >1000μF, add 0,02 per another 1000μF |
| Low Temperature Characteristics |
Impedance ratio max. at 120Hz
| Working Voltage (V) |
6,3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| Z-25°C / Z+20°C |
4 |
3 |
2 |
2 |
2 |
2 |
2 |
2 |
| 2-40°0 / Z+20°0 |
10 |
8 |
6 |
4 |
3 |
3 |
3 |
3 |
For capacitance value >1000μF,
Add 0,5 per another 1000μF for Z-25°C / Z+20°C
Add 1,0 per another 1000μF for Z-40°C / Z+20°C |
| High Temperature Loading |
| Test conditions |
Post test requirements at +20°C |
Duration:
| WV |
6,3 to 100 |
| ØD |
5 to 8 |
10 to 18 |
| Load life |
1000h |
2000h |
|
Leakage current: ≤ Initial specified value |
| Ambient temp.: +105°C |
Cap. change: within ±20% of initial measured value |
| Applied voltage: Rated DC working voltage with max. ripple current |
tan δ: ≤ 200% of initial specified value |
|
| Shelf Life |
| Test conditions |
Post test requirements at +20°C |
| Duration: 1000 hours |
Same limits for high temperature loading. |
| Ambient temp.: +105°C |
|
| Applied voltage: (None) |
|
|
| Others |
JIS C - 5101 (IEC 60384) |
STANDARD RATINGS
| Voltage (Code) |
6,3V (0J) |
10V (1A) |
16V (1C) |
| Cap, (μF) |
Code |
Case Size
ØDxL (mm) |
Impedance |
Ripple
Current |
Case Size
ØDxL (mm) |
Impedance |
Ripple
Current |
Case Size
ØDxL (mm) |
Impedance |
Ripple
Current |
| 10 |
106 |
|
|
|
|
|
|
4x5 |
5,0 |
50 |
| 15 |
156 |
|
|
|
|
|
|
5x5 |
2,6 |
80 |
| 22 |
226 |
4x5 |
5,0 |
50 |
5x5 |
2,6 |
80 |
5x5 |
2,6 |
80 |
| 33 |
336 |
5x5 |
2,6 |
80 |
5x5 |
2,6 |
80 |
6,3x5 |
1,3 |
115 |
| 47 |
476 |
5x5 |
2,6 |
80 |
6,3x5 |
1,3 |
115 |
6,3x5 |
1,3 |
115 |
| 68 |
686 |
6,3x5 |
1,3 |
115 |
|
|
|
|
|
|
| 100 |
107 |
6,3x5 |
1,3 |
115 |
|
|
|
|
|
|
Maximum Allowable Ripple Current (mA rms) at 105°C 120Hz
Maximum Impedance (Ω) at 20°C 100kHz |
| Voltage (Code) |
25V (1E) |
35V (1V) |
| Cap, (μF) |
Code |
Case Size
ØDxL (mm) |
Impedance |
Ripple
Current |
Case Size
ØDxL (mm) |
Impedance |
Ripple
Current |
| 1 |
105 |
|
|
|
4x5 |
5,0 |
50 |
| 1,5 |
155 |
|
|
|
4x5 |
5,0 |
50 |
| 2,2 |
225 |
|
|
|
4x5 |
5,0 |
50 |
| 3,3 |
335 |
|
|
|
4x5 |
5,0 |
50 |
| 4,7 |
475 |
4x5 |
5,0 |
50 |
4x5 |
5,0 |
50 |
| 6,8 |
685 |
4x5 |
5,0 |
80 |
5x5 |
2,6 |
80 |
| 10 |
106 |
5x5 |
2,6 |
80 |
5x5 |
2,6 |
80 |
| 15 |
156 |
6,3x5 |
1,3 |
115 |
6,3x5 |
1,3 |
115 |
| 22 |
226 |
6,3x5 |
1,3 |
115 |
6,3x5 |
1,3 |
115 |
| 33 |
336 |
6,3x5 |
1,3 |
115 |
|
|
|
Maximum Allowable Ripple Current (mA rms) at 105°C 120Hz
Maximum Impedance (Ω) at 20°C 100kHz |
RIPPLE CURRENT MULTIPLIER
Frequency Coefficient (Hz)
| Cap (μF) |
120 |
1k |
10k |
100k |
| ~100 |
0,40 |
0,75 |
0,90 |
1,00 |
|