Model |
HLG-150-12 |
HLG-150-20 |
HLG-150-24 |
HLG-150-36 |
HLG-150-48 |
output |
DC voltage |
12V |
20V |
24V |
36V |
48V |
Constant current region |
6~12V |
10~20V |
12~24V |
18~36V |
24~48V |
Rated current |
12.5A |
7.5A |
6.3A |
4.2A |
3.2A |
Rated power |
150W |
150W |
151.2W |
151.2W |
153.6W |
Ripple&noise |
150mvp-p |
150mvp-p |
150mvp-p |
200mvp-p |
200mvp-p |
Voltage ADJ range |
10.8~13.5V |
17~22V |
22~27V |
33~40V |
43~53V |
Current ADJ range |
Can be adjusted by internal potentiometer or through output cable |
|
6.5~12.5A |
4.65~7.5A |
3.9~6.3A |
2.6~4.2A |
1.95~3.2A |
input |
Voltage range |
90~264VAC, 47~63HZ , 127~370VDC |
AC current |
1.7A/115VAC, 0.75A/230VAC |
Power factor |
PF>0.95/230VAC,PF>0.98/115VAC Start overload protection |
Efficiency |
92% |
92% |
93% |
93% |
94% |
Inrush current |
Cold start current 35A/115VAC, 75A/230VAC |
Leakage current |
< 0.75mA/240VAC |
protection |
Over current |
95%~108% |
protection type :Constant current limiting, auto-recovery after fault condition is removed |
Short circuit |
Hiccup mode, recovers automatically after fault condition is remove |
Over voltage |
14~17V |
23~27V |
28~34V |
41~46V |
54~60V |
protection type:Shut down o/p voltage re-power on to recover |
Over temperature |
100°C±10°C(RTH2) |
protection type:Shut down o/p voltage re-power on to recover |
environment |
Working temp, humidity |
-20°C~+60, 20%~90%RH |
Storage temp, humidity |
-40°C~+85, 10%~95%RH non-condensing |
Withstand vibration |
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes |
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
fit standard |
Safety standard |
Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved |
EMC standard |
Fit EN55015, EN61000-3-2 ClassC(>60%load):EN61000-3-3 |
others |
Dimension |
231*69*39mm (L*W*H) |
Weight/packing |
1.1kg/20pcs/23kg/0.03m3/1.07CUFT |
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12"
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. |