Bentex
  Company Profile
  Products
  Contact Us

Products:
Battery Holders
Capacitors
Connectors
Gas tubes
Heat Sinks
ICs >> STM32 microcontrollers
LCD Module
LED Display
LED Lens
LED Lights
LED Module
Materials
Miniature Speakers
Plastic & Hardware
Potentiometers & Encoders
Resistors
Power Supplies
Power supply filters
Quartz Crystal
Switches
Test Probes
Thermistors
Varistors

 

Power Supplies / LPA Series /

LPA-100W series

LED constant current waterproof power supply

Features:
-Constant current style power supply
- 180~264VAC AC input
- Small volume, low weight, high efficiency
- Protections:short circuit/over load/over temp
- Cooling by free air convection
- Fully encapsulated with IP67 level
- 100% full load burn-in test
- 1 year warranty

Model LPA-100-3500 LPA-100-2800 LPA-100-2100
output DC voltage 3500mA 2800mA 2100mA
Voltage tolerance 16~28V 22~35V 28~47V
Rated current 98W 98W 98.7W
Current range 200mvp-p 200mvp-p 200mvp-p
Rated power ±5% ±5% ±5%
Ripple&noise ±2% ±2% ±2%
input Voltage range 180~260VAC, 238~370VDC
Frequency 47~63HZ
AC current 1.2A/230VAC
Efficiency 86%
Inrush current Cold start current 55A/230VAC
Leakage current <0.5mA/240VAC
protection Over load ±5% Rated current
protection type: rated current limit
Over temperature Shell temp>85°C±10°C(JK1), start over temperature protection
protection mode: cutoff output, auto-recovery after temperature become normal
environment Workingtemp, humidity -10°C~+60, 20%~90%RH
Storage temp.humidity -20°C~+85, 10%~95%RH non condensing
Withstand vibration 10~500HZ, 2G 10min/1cycle, period for 60minutes, each axes
safety Withstand voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P, I/P-FG, O/P-FG:100M ohms/500VDC
fit standard Safety standard Fit UL1012, IP67 protect level
eMC standard Fit EN55022, CLASS A
others Dimension 185*69*43mm (L*W*H)
Weight/packing 0.9kg/20pcs/19kg/0.026 m3/0.91CUFT
note 1. All parameters NOT specially mentioned are measured at 230VAC input,
rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using
a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.