SC-60W series
|
UPS function monitor power supply
Features:
- Universal AC input
- Small volume, low weight, high efficiency
- Protections:short circuit/over load
- Indicator for power on/charge/normal(LED)
- 100% full load burn-in test
- Battery protection at low voltage
- 2 year warranty |
Model |
SC-60-12 |
SC-60-24 |
output |
DC voltage |
CH1: 13.8V |
CH1: 13.4V |
CH1: 27.6V |
CH2: 26.5V |
Voltage tolerance |
±1% |
- ---- |
±1% |
- ---- |
Rated current |
4.0A |
0.35A |
2.0A |
0.25A |
Current range |
0~4A |
- ---- |
0~2A |
- ---- |
Rated power |
59.9W |
61.8W |
Ripple&noise |
100mvp-p |
- ---- |
100mvp-p |
- ---- |
DCvoltage ADJ.range |
CH1: 11.3~14.9V |
CH1: 21.3~29.8V |
input |
Voltage range |
90~264VAC, 127~370VDC |
Frequency |
47~63HZ |
AC current |
1.6A/115VAC, 0.8A/230VAC |
Efficiency |
81% |
83% |
Inrush current |
Cold start current 25A/115VAC, 45A/230VAC |
Leakage current |
< 1mA/240VAC |
protection |
Over load |
Rated output power 110%~150% start over load protection |
protection mode: AC charging mode: hiccup mode auto-recovery after fault condition is removed |
Battery protection
At low voltage |
9.5~11V |
20~22V |
protection mode: cutoff output |
function |
UPS introduction |
Long-term
online floating charge to battery, high charging efficiency,
battery can
saturate to more than 90%, cauto-stop harging when it's full,
prevent
over charging.
Effectively extend battery life, AC/battery auto switch,
no
switch time,no need human guard,
Cold-start, when there is no AC input,
can use battery start UPS, Meet the user's emergency needs |
environment |
Working temp, humidity |
-10°C~+60, 20%~90%RH |
Storage temp, humidity |
-20°C~+85, 10%~95%RH non-condensing |
Withstand vibration |
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes |
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
fit standard |
Safety standard |
Compliance to UL60950-1 |
EMC standard |
Compliance to EN55022, CLASSB |
others |
Dimension |
129*98*38mm (L*W*H) |
Weight/packing |
0.52kg/45pcs/24kg/0.034m3/1.2CUFT |
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12"
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. |
|