Bentex
  Company Profile
  Products
  Contact Us

Products:
Battery Holders
Capacitors
Connectors
Gas tubes
Heat Sinks
ICs >> STM32 microcontrollers
LCD Module
LED Display
LED Lens
LED Lights
LED Module
Materials
Miniature Speakers
Plastic & Hardware
Potentiometers & Encoders
Resistors
Power Supplies
Power supply filters
Quartz Crystal
Switches
Test Probes
Thermistors
Varistors

 

Power Supplies / T Series /

T-30W series

Normal triple switching power supply

Features:
- AC input voltage range selected by switch
- Small volume, low weight, high efficiency
- Protections:short circuit/over load
- LED indicator for power on
- 100% full load burn-in test
- 2 year warranty

Model T-30A T-30B
output DC voltage CH1: +5V CH2: +12V CH3:-5V CH1: +5V CH2: +12V CH3:-12V
Voltage tolerance ±2% +4%~-6% +5%~-10% ±2% +4%~-6% +5%~-10%
Rated current 3A 1A 0.5A 3A 1A 0.5A
Current range 0.6~3A 0.1~1A 0.1~0.5A 0.6~3A 0.1~1A 0.1~0.5A
Rated power 30W 33W
Ripple&noise 80mvp-p 100mvp-p 100mvp-p 80mvp-p 100mvp-p 100mvp-p
DCvoltage ADJ.range CH1: -9%~+10%
input Voltage range 90~132VAC / 180~264VAC (selected by switch), 255~373VDC
Frequency 47~63HZ
AC current 0.8A/115VAC, 0.45A/230VAC
Efficiency 73%       74%
Inrush current Cold start current 18A/115VAC, 36A/230VAC
Leakage current < 2mA/240VAC
protection Overload Rated output power 110%~150 start over load protection
protection type: part layer type current limit, auto-recovery after fault condition is removed
environment Working temp, humidity -10°C~+60, 20%~90%RH
Storage temp, humidity -20°C~+85, 10%~95%RH non-condensing
Withstand vibration 10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes
safety Withstand voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC
fit standard Safety standard Fit UL1012
EMC standard EN55022, CLASS A
others Dimension 129*98*38mm (L*W*H)
Weight/packing 0.4kg/45pcs/19kg/0.034m3/1.2CUFT
note 1. All parameters NOT specially mentioned are measured at 230VAC input,
rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using
a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.